GSM 365-450W BF Framed

Mono-crystalline Bifacial Solar Module / 72 cells / Framed
Premium BF Series with 10-30% Power Generation Gain
  • The power generation increased by reflected light 10-30%
  • Zero light degradation (LID)
  • Enhanced safety by excellent fire resistance
  • Frameless design is perfect for sandy, snowy and high latitude regions
  • Positive power tolerance 0/+5W
  • Bankable module
  • PID free
  • Advanced surface texturing
  • Resistance to sand and dust abrasion
  • Safety for salt mist and ammonia corrosion
  • Outstanding power output capability at low irradiance
  • Triple 100% EL tests
  • 3800 Pa wind load and 5400 Pa snow load (900 kg snow load per module); 35 mm hail stones at 97 km/h
Data Sheet (PDF)

QUALIFICATIONS AND CERTIFICATES

CE-Compliant, IEC 61215 (Ed.1) IEC 61730 application class A, Safety Class II, UL 1703

iso iec ce Tuev-nord UL safety-class-2

WARRANTY

  • 15 Years: Manufacturing Warranty   100%
  • 12 Years Warranty: 90% Power Output   90%
  • 30 Years Warranty: 80% Power Output   80%
Cell type Mono-crystalline
No. of Cells 72 (6×12)
Module Dimensions 1980 × 992 × 35/40 mm
Weight 26.1 kg
Front Glass / Back Glass 2.0 mm tempered glass
Frame Anodized aluminum alloy
Junction Box IP68 (distributed junction box)
Connector MC4 compatible
Output Cables 4.0 mm2, asymmetrical lengths (-) 350 mm, (+) 160 mm
Mechanical load 5400 Pa

 

Model GSM 365-440W
BF framed
GSM 370-445W
BF framed
GSM 375-450W
BF framed
Performance at Standard Test Conditions (STC): 1000 W/m2, 25°C, AM 1.5
Testing Conditions Front Side / Rear Side Front Side / Rear Side Front Side / Rear Side
Maximum Power (Pmax) 365 W / 310 W 370 W / 314 W 375 W / 319 W
Operating Voltage (Vmpp) 38.2 V / 38.0 V 38.4 V / 38.2 V 38.5 V / 38.3 V
Operating Current (Impp) 9.56 A / 8.15 A 9.66 A / 8.24 A 9.75 A / 8.32 A
Open-Circuit Voltage (Voc) 44.8 V / 44.4 V 45.0 V / 44.6 V 45.1 V / 44.7 V
Short-Circuit Current (Isc) 10.13 A / 8.68 A 10.23 A / 8.76 A 10.32 A / 8.83 A
Module Efficiency 18.6 % / 15.8 % 18.8 % / 16.0 % 19.1 % /16.2 %
Performance at Nominal Operating Cell Temperature (NOCT) : 800 W/m2, 20°C, AM 1.5, wind speed 1m/s
Testing Conditions Front Side / Rear Side Front Side / Rear Side Front Side / Rear Side
Maximum Power (Pmax) 268 W / 228 W 272 W / 231 W 276 W / 234 W
Operating Voltage (Vmpp) 35.1 V / 35.0 V 35.2 V / 35.1 V 35.3 V / 35.2 V
Operating Current (Impp) 7.65 A / 6.52 A 7.73 A / 6.59 A 7.80 A / 6.65 A
Open-Circuit Voltage (Voc) 41.4 V / 41.1 V 41.6 V / 41.3 V 41.7 V / 41.4 V
Short-Circuit Current (Isc) 8.17 A / 7.0 A 8.24 A / 7.06 A 8.32 A / 7.12 A
Power Tolerance 0 /+5 W
Maximum System Voltage 1500 VDC (IEC) / 1000 VDC (UL)
Maximum Series Fuse 15 A
Temperature Characteristics
Temperature Coefficient at Pmax – 0.38% / °C
Temperature Coefficient at Voc – 0.30 % / °C
Temperature Coefficient at Isc + 0.048 % / °C
Nominal Operating Cell Temperature 42 ± 2 °C
Operating Temperature -40 °C to 85 °C

With Different Power Generation Gain (360S)

Power Gain Max. Power
(Pmax)
MPP Voltage
(Vmpp)
MPP Current
(Impp)
Open-Circuit Voltage
(Voc)
Short-Circuit Voltage
(Isc)
10% 391 W 38.1 V 10.26 A 44.7 V 10.90 A
15% 406 W 38.1 V 10.66 A 44.7 V 11.33 A
20% 421 W 38.1 V 11.05 A 44.8 V 11.72 A
25% 437 W 38.2 V 11.44 A 44.8 V 12.14 A
30% 452 W 38.2 V 11.83 A 44.8 V 12.55 A

I-V Curves

curve1 Irradiance Dependence of Isc, Voc

curve2Temperature Dependence of Isc, Voc

Get In Touch

If you are interested in working together, send us an inquiry and we will get back to you as soon as we can!

Contact